{"id":10604,"date":"2015-05-08T06:00:59","date_gmt":"2015-05-08T04:00:59","guid":{"rendered":"https:\/\/www.johner-institut.de\/blog\/?p=10604"},"modified":"2023-04-10T10:28:10","modified_gmt":"2023-04-10T08:28:10","slug":"fhir-interoperabilitaetsstandard","status":"publish","type":"post","link":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/","title":{"rendered":"FHIR: Endlich mal ein praxisnaher Interoperabilit\u00e4tsstandard"},"content":{"rendered":"<p>Mit FHIR (gesprochen: Fire)\u00a0hat HL7\u00a0einen modernen Interoperabilit\u00e4tsstandard entwickelt, dem ich gro\u00dfes Zukunftspotenzial zutraue.<br \/>\nErfahren Sie mehr \u00fcber <a href=\"https:\/\/www.johner-institut.de\/blog\/tag\/interoperabilitat\/\">Interoperabilit\u00e4t<\/a>.<\/p>\n<p><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png\" data-rel=\"lightbox-image-0\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10605\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png\" alt=\"Logo von FHIR\" width=\"140\" height=\"60\" \/><\/a><\/p>\n<p><!--more--><\/p>\n<h2>Was FHIR wie standardisiert<\/h2>\n<p><a href=\"http:\/\/hl7.org\/fhir\/\" target=\"_blank\" rel=\"noopener noreferrer\">FHIR<\/a> ist ein neuer Interoperabilit\u00e4tsstandard speziell f\u00fcr das Gesundheitswesen, der auf\u00a0<a href=\"http:\/\/de.wikipedia.org\/wiki\/Representational_State_Transfer\" target=\"_blank\" rel=\"noopener noreferrer\">REST<\/a>\u00a0basiert. Damit verbindet er die Konzepte von HL7 V3 mit modernen Internetstandards.<\/p>\n<p>Auf Ressourcen wie Patienten, Medikamente oder Behandlungen greift man \u00fcber URLs zu. Beispielsweise w\u00fcrde man auf\u00a0den\u00a0Patient mit der ID 1235 zugreifen \u00fcber<\/p>\n<p>GET https:\/\/www.krankenhaus.de\/kis\/patient\/1235<\/p>\n<p>\u00c4ndern w\u00fcrde man Daten dem REST-Paradigma folgend \u00fcber die HTTP-Methode PUT, l\u00f6schen \u00fcber DELETE und erzeugen via POST.<\/p>\n<p>Als R\u00fcckgabeformate kann man zwischen XML und JSON w\u00e4hlen. Das l\u00e4sst sich \u00fcber die URL ebenfalls bestimmen, beispielsweise:<\/p>\n<p>GET https:\/\/www.krankenhaus.de\/kis\/patient\/1235?_format?json<\/p>\n<p>Die Daten\u00a0k\u00f6nnen auch von\u00a0Menschen lesbare Anteile (in HTML) enthalten, wie folgende Abbildung von <a href=\"http:\/\/hl7.org\/fhir\/\" target=\"_blank\" rel=\"noopener noreferrer\">HL7<\/a> zeigt:<\/p>\n<p><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-beispiel-quelle-hl7.png\" data-rel=\"lightbox-image-1\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-10606\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-beispiel-quelle-hl7.png\" alt=\"FHIR: Ein Beispiel von HL7\" width=\"675\" height=\"563\" srcset=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-beispiel-quelle-hl7.png 675w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-beispiel-quelle-hl7-300x250.png 300w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/a><\/p>\n<p>Der FHIR Standard adressiert\u00a0somit mehrere\u00a0Ebenen des Interoperabilit\u00e4tsstacks:<\/p>\n<ul>\n<li>Strukturelle\u00a0Interoperabilit\u00e4t: Standard Internetprotokolle insbesondere HTTP(S)<\/li>\n<li>Syntaktische Interoperabilit\u00e4t: JSON und XML<\/li>\n<li>Semantische Interoperabilit\u00e4t: Datentypen, Ordnungssysteme,\u00a0definierte XML-Tags bzw. JSON-Elemente<\/li>\n<\/ul>\n<p>Beispiel:<\/p>\n<p>Ein Laborwert w\u00e4re in XML kodiert mit:<\/p>\n<pre class=\"xml\">&lt;<b>coding<\/b>&gt;\r\n   &lt;<b>system<\/b> value=\"http:\/\/loinc.org\"\/&gt;\r\n   &lt;<b>code<\/b> value=\"2947-0\"\/&gt;\r\n &lt;\/<b>coding<\/b>\/&gt;<\/pre>\n<p>In JSON s\u00e4he das so aus:<\/p>\n<pre class=\"json\">\"coding\": [\r\n   {\r\n     \"system\" : \"http:\/\/loinc.org\",\r\n     \"code\" : \"2947-0\"\r\n   }\r\n ]<\/pre>\n<p>Damit sind Entwickler alle sehr vertraut, so dass sie sich dank FHIR bald in der Lage sehen, nicht nur Nachrichten, sondern auch Dokumente zu \u00fcbertragen.<\/p>\n<h2>Weshalb FHIR\u00a0erfolgreich sein wird<\/h2>\n<p>Ich bin von FHIR \u00fcberzeugt, aus mehreren Gr\u00fcnden:<\/p>\n<ol>\n<li>Man kann es verstehen! Was banal klingt, ist leider keinen Selbstverst\u00e4ndlichkeit. Nach\u00a0einer mehrt\u00e4gigen HL7 V3 Schulung\u00a0konnte man bestenfalls die Konzepte verstehen. Aber wirklich damit\u00a0arbeiten konnte niemand. Die Dokumentation war ebenso umfangreich wie un\u00fcbersichtlich.\u00a0Zumindest der Einstieg d\u00fcrfte f\u00fcr jeden Entwickler nun ein Kinderspiel sein. Beispiele, S<\/li>\n<li>Die Dokumentation von FHIR ist \u00f6ffentlich zug\u00e4nglich, die Spezifikation darf kostenfrei genutzt werden.<\/li>\n<li>Die Modellierung entspricht \u00fcblichen Vorgehensmodellen und ist logisch. W\u00e4hrend meiner Zeit in Stanford machten sich die dortigen Professoren dar\u00fcber lustig und bezeichneten den ganzen Ansatz von HL7 V3 als Negativbeispiel.<\/li>\n<li>Die Spezifikation\u00a0greift \u00fcbliche Ans\u00e4tze (wie z.B. den von REST) auf. Keine eigenen Notationssprachen, verschwurbelten Konzepte wie Class Codes statt Vererbung&#8230;<\/li>\n<li>Die FHIR Spezifikation ist so vollst\u00e4ndig, das man sofort damit starten kann.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mit FHIR (gesprochen: Fire)\u00a0hat HL7\u00a0einen modernen Interoperabilit\u00e4tsstandard entwickelt, dem ich gro\u00dfes Zukunftspotenzial zutraue. Erfahren Sie mehr \u00fcber Interoperabilit\u00e4t.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":true,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[5],"tags":[198,651,1107,269,680],"ppma_author":[1210],"class_list":["post-10604","post","type-post","status-publish","format-standard","hentry","category-gesundheitswesen","tag-interoperabilitat","tag-informationssysteme","tag-krankenhaus","tag-medizinische-software","tag-standalone-software","category-5","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FHIR - Interoperabilit\u00e4tsstandard von HL7 ~ Schnittstellenspezifikation<\/title>\n<meta name=\"description\" content=\"Mit FHIR hat HL7 (endlich) einen REST-basierten Interoperabilit\u00e4tsstandard entworfen, dem ich gro\u00dfe Zukunft vorhersage. Damit wird HL7 V3 revitalisiert.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FHIR - Interoperabilit\u00e4tsstandard von HL7 ~ Schnittstellenspezifikation\" \/>\n<meta property=\"og:description\" content=\"Mit FHIR hat HL7 (endlich) einen REST-basierten Interoperabilit\u00e4tsstandard entworfen, dem ich gro\u00dfe Zukunft vorhersage. Damit wird HL7 V3 revitalisiert.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/\" \/>\n<meta property=\"og:site_name\" content=\"Regulatorisches Wissen f\u00fcr Medizinprodukte\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/JohnerInstitut\/\" \/>\n<meta property=\"article:published_time\" content=\"2015-05-08T04:00:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-04-10T08:28:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png\" \/>\n<meta name=\"author\" content=\"Prof. Dr. Christian Johner\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Prof. Dr. Christian Johner\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/\"},\"author\":{\"name\":\"Prof. Dr. Christian Johner\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/person\\\/77ee54cd54e987c0b5738d4cb4c80441\"},\"headline\":\"FHIR: Endlich mal ein praxisnaher Interoperabilit\u00e4tsstandard\",\"datePublished\":\"2015-05-08T04:00:59+00:00\",\"dateModified\":\"2023-04-10T08:28:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/\"},\"wordCount\":384,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/04\\\/fhir-logo-www.png\",\"keywords\":[\"Interoperabilit\u00e4t - auch gesetzlich verpflichtend\",\"Klinische Informationssysteme\",\"Krankenh\u00e4user - Labore - Praxen und andere Betreiber\",\"Medizinische Software \\\/ Medical Device Software\",\"Standalone-Software\"],\"articleSection\":[\"Gesundheitswesen &amp; Health IT\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/\",\"name\":\"FHIR - Interoperabilit\u00e4tsstandard von HL7 ~ Schnittstellenspezifikation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/04\\\/fhir-logo-www.png\",\"datePublished\":\"2015-05-08T04:00:59+00:00\",\"dateModified\":\"2023-04-10T08:28:10+00:00\",\"description\":\"Mit FHIR hat HL7 (endlich) einen REST-basierten Interoperabilit\u00e4tsstandard entworfen, dem ich gro\u00dfe Zukunft vorhersage. Damit wird HL7 V3 revitalisiert.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/04\\\/fhir-logo-www.png\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/04\\\/fhir-logo-www.png\",\"width\":140,\"height\":60,\"caption\":\"Logo von FHIR\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/gesundheitswesen\\\/fhir-interoperabilitaetsstandard\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Gesundheitswesen &amp; Health IT\",\"item\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/category\\\/gesundheitswesen\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"FHIR: Endlich mal ein praxisnaher Interoperabilit\u00e4tsstandard\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\",\"name\":\"Regulatorisches Wissen f\u00fcr Medizinprodukte\",\"description\":\"Fachartikel zur Entwicklung und Zulassung von Medizinprodukten und weiteren regulatorischen Themen\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\",\"name\":\"Johner Institut GmbH\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/07\\\/Johner-Institut.png\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/07\\\/Johner-Institut.png\",\"width\":1213,\"height\":286,\"caption\":\"Johner Institut GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/JohnerInstitut\\\/\",\"https:\\\/\\\/x.com\\\/christianjohner\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/JohnerInstitut\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/person\\\/77ee54cd54e987c0b5738d4cb4c80441\",\"name\":\"Prof. Dr. Christian Johner\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Christian_Johner.jpgab057afc2debeb41aaf55cce7e79e618\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Christian_Johner.jpg\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/05\\\/Christian_Johner.jpg\",\"caption\":\"Prof. Dr. Christian Johner\"},\"description\":\"Professor Johner ist Experte f\u00fcr die Entwicklung und Zulassung von Medizinprodukten, die Software enthalten oder Software sind. Als Auditor, als Mitglied eines Normen-Komitees, als Ausbilder benannter Stellen sowie als Autor mehrerer B\u00fccher und Leitf\u00e4den tr\u00e4gt der promovierte Physiker zur Weiterentwicklung der regulatorischen Landschaft bei. Davon zeugen auch Leitf\u00e4den, die er f\u00fcr die WHO und die Benannten Stellen entwickelt hat. Sein Unternehmen, das Johner Institut, unterst\u00fctzt Medizinproduktehersteller weltweit beim Aufbau von QM-Systemen, bei der Zulassung und Pr\u00fcfung ihrer Produkte sowie bei der digitalen Transformation regulatorischer Prozesse. Es bietet Weiterbildungen wie E-Learning und Seminare an und \u00fcbernimmt f\u00fcr Hersteller Prozesse wie die \u00dcberwachung der Regularien und der Produkte im Markt. Christian Johner lehrte an mehreren Universit\u00e4ten u.a. an der Hochschule Konstanz, der Universit\u00e4t St. Gallen, der Universit\u00e4t W\u00fcrzburg sowie der Stanford University v.a. Software-Architektur, Software-Qualit\u00e4tssicherung und medizinische Informatik.\",\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/in\\\/christianjohner\\\/\",\"https:\\\/\\\/x.com\\\/christianjohner\"],\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/author\\\/christian\\\/\"}]}<\/script>\n<meta name=\"copyright\" content=\"Johner Institut GmbH\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FHIR - Interoperabilit\u00e4tsstandard von HL7 ~ Schnittstellenspezifikation","description":"Mit FHIR hat HL7 (endlich) einen REST-basierten Interoperabilit\u00e4tsstandard entworfen, dem ich gro\u00dfe Zukunft vorhersage. Damit wird HL7 V3 revitalisiert.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/","og_locale":"de_DE","og_type":"article","og_title":"FHIR - Interoperabilit\u00e4tsstandard von HL7 ~ Schnittstellenspezifikation","og_description":"Mit FHIR hat HL7 (endlich) einen REST-basierten Interoperabilit\u00e4tsstandard entworfen, dem ich gro\u00dfe Zukunft vorhersage. Damit wird HL7 V3 revitalisiert.","og_url":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/","og_site_name":"Regulatorisches Wissen f\u00fcr Medizinprodukte","article_publisher":"https:\/\/www.facebook.com\/JohnerInstitut\/","article_published_time":"2015-05-08T04:00:59+00:00","article_modified_time":"2023-04-10T08:28:10+00:00","og_image":[{"url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png","type":"","width":"","height":""}],"author":"Prof. Dr. Christian Johner","twitter_misc":{"Verfasst von":"Prof. Dr. Christian Johner","Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#article","isPartOf":{"@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/"},"author":{"name":"Prof. Dr. Christian Johner","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/person\/77ee54cd54e987c0b5738d4cb4c80441"},"headline":"FHIR: Endlich mal ein praxisnaher Interoperabilit\u00e4tsstandard","datePublished":"2015-05-08T04:00:59+00:00","dateModified":"2023-04-10T08:28:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/"},"wordCount":384,"commentCount":1,"publisher":{"@id":"https:\/\/www.johner-institut.de\/blog\/#organization"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#primaryimage"},"thumbnailUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png","keywords":["Interoperabilit\u00e4t - auch gesetzlich verpflichtend","Klinische Informationssysteme","Krankenh\u00e4user - Labore - Praxen und andere Betreiber","Medizinische Software \/ Medical Device Software","Standalone-Software"],"articleSection":["Gesundheitswesen &amp; Health IT"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/","url":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/","name":"FHIR - Interoperabilit\u00e4tsstandard von HL7 ~ Schnittstellenspezifikation","isPartOf":{"@id":"https:\/\/www.johner-institut.de\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#primaryimage"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#primaryimage"},"thumbnailUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png","datePublished":"2015-05-08T04:00:59+00:00","dateModified":"2023-04-10T08:28:10+00:00","description":"Mit FHIR hat HL7 (endlich) einen REST-basierten Interoperabilit\u00e4tsstandard entworfen, dem ich gro\u00dfe Zukunft vorhersage. Damit wird HL7 V3 revitalisiert.","breadcrumb":{"@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#primaryimage","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/04\/fhir-logo-www.png","width":140,"height":60,"caption":"Logo von FHIR"},{"@type":"BreadcrumbList","@id":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/fhir-interoperabilitaetsstandard\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Blog","item":"https:\/\/www.johner-institut.de\/blog\/"},{"@type":"ListItem","position":2,"name":"Gesundheitswesen &amp; Health IT","item":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},{"@type":"ListItem","position":3,"name":"FHIR: Endlich mal ein praxisnaher Interoperabilit\u00e4tsstandard"}]},{"@type":"WebSite","@id":"https:\/\/www.johner-institut.de\/blog\/#website","url":"https:\/\/www.johner-institut.de\/blog\/","name":"Regulatorisches Wissen f\u00fcr Medizinprodukte","description":"Fachartikel zur Entwicklung und Zulassung von Medizinprodukten und weiteren regulatorischen Themen","publisher":{"@id":"https:\/\/www.johner-institut.de\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.johner-institut.de\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.johner-institut.de\/blog\/#organization","name":"Johner Institut GmbH","url":"https:\/\/www.johner-institut.de\/blog\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/07\/Johner-Institut.png","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/07\/Johner-Institut.png","width":1213,"height":286,"caption":"Johner Institut GmbH"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/JohnerInstitut\/","https:\/\/x.com\/christianjohner","https:\/\/www.youtube.com\/user\/JohnerInstitut"]},{"@type":"Person","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/person\/77ee54cd54e987c0b5738d4cb4c80441","name":"Prof. Dr. Christian Johner","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/Christian_Johner.jpgab057afc2debeb41aaf55cce7e79e618","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/Christian_Johner.jpg","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/Christian_Johner.jpg","caption":"Prof. Dr. Christian Johner"},"description":"Professor Johner ist Experte f\u00fcr die Entwicklung und Zulassung von Medizinprodukten, die Software enthalten oder Software sind. Als Auditor, als Mitglied eines Normen-Komitees, als Ausbilder benannter Stellen sowie als Autor mehrerer B\u00fccher und Leitf\u00e4den tr\u00e4gt der promovierte Physiker zur Weiterentwicklung der regulatorischen Landschaft bei. Davon zeugen auch Leitf\u00e4den, die er f\u00fcr die WHO und die Benannten Stellen entwickelt hat. Sein Unternehmen, das Johner Institut, unterst\u00fctzt Medizinproduktehersteller weltweit beim Aufbau von QM-Systemen, bei der Zulassung und Pr\u00fcfung ihrer Produkte sowie bei der digitalen Transformation regulatorischer Prozesse. Es bietet Weiterbildungen wie E-Learning und Seminare an und \u00fcbernimmt f\u00fcr Hersteller Prozesse wie die \u00dcberwachung der Regularien und der Produkte im Markt. Christian Johner lehrte an mehreren Universit\u00e4ten u.a. an der Hochschule Konstanz, der Universit\u00e4t St. Gallen, der Universit\u00e4t W\u00fcrzburg sowie der Stanford University v.a. Software-Architektur, Software-Qualit\u00e4tssicherung und medizinische Informatik.","sameAs":["https:\/\/www.linkedin.com\/in\/christianjohner\/","https:\/\/x.com\/christianjohner"],"url":"https:\/\/www.johner-institut.de\/blog\/author\/christian\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack-related-posts":[{"id":4487573,"url":"https:\/\/www.johner-institut.de\/blog\/iec-62304-medizinische-software\/fhir-profile\/","url_meta":{"origin":10604,"position":0},"title":"FHIR: In drei Schritten zum eigenen Profil","author":"Prof. Dr. Christian Johner","date":"30. November 2021","format":false,"excerpt":"FHIR ist inzwischen der Standard f\u00fcr den Datenaustausch im Gesundheitswesen. Moderne klinische Informationssysteme, viele Medizinprodukte und selbst Health-Apps kommen an FHIR nicht vorbei. FHIR steht f\u00fcr \"Fast Healthcare Interoperability Resources\" und wird wie das englische \u201efire\u201c ausgesprochen. Dieser von HL7 ins Leben gerufene Standard soll alle \u201eUse Cases\u201c abdecken: vom\u2026","rel":"","context":"In &quot;Gesundheitswesen &amp; Health IT&quot;","block_context":{"text":"Gesundheitswesen &amp; Health IT","link":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2021\/11\/Forge-Profile-02.jpeg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":3430,"url":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/loinc-logical-observation-identifiers-names-and-codes\/","url_meta":{"origin":10604,"position":1},"title":"LOINC &#8212; Logical Observation Identifiers Names and Codes","author":"Prof. Dr. Christian Johner","date":"5. Juli 2018","format":false,"excerpt":"LOINC, die\u00a0Logical Observation Identifiers Names and Codes, sind ein vom Regenstrief Institute gepflegtes System, um v.a. Laborparameter und Vitaldaten semantisch eindeutig zu verschl\u00fcsseln. Zunehmend findet das System auch in Deutschland Beachtung, auch von den Medizintechnik-Unternehmen. Die FDA legt diesen semantischen Standard besonders den IVD-Herstellern nahe. Mit Recht! \u00a0Inhalts\u00fcbersicht Ziele von\u2026","rel":"","context":"In &quot;Gesundheitswesen &amp; Health IT&quot;","block_context":{"text":"Gesundheitswesen &amp; Health IT","link":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/11\/LOINC-300x152.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":4583377,"url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/telematikinfrastruktur\/","url_meta":{"origin":10604,"position":2},"title":"Telematikinfrastruktur: 5 Anforderungen, die Software-Hersteller beachten m\u00fcssen","author":"Prof. Dr. Christian Johner","date":"19. April 2024","format":false,"excerpt":"Die Telematikinfrastruktur (TI) ist eine Plattform bzw. ein Netzwerk, \u00fcber das in Deutschland Gesundheitsdaten sicher ausgetauscht werden und auf der Gesundheitsanwendungen wie die elektronische Patientenakte und das e-Rezept betrieben werden sollen. Dieser Beitrag hilft Herstellern medizinischer Software zu verstehen, wann sie welche gesetzlichen und technischen Anforderungen im Kontext dieser Telematikinfrastruktur\u2026","rel":"","context":"In &quot;Gesundheitswesen &amp; Health IT&quot;","block_context":{"text":"Gesundheitswesen &amp; Health IT","link":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/01\/Telematikinfrastruktur-small.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/01\/Telematikinfrastruktur-small.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/01\/Telematikinfrastruktur-small.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/01\/Telematikinfrastruktur-small.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":762427,"url":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/internet-der-dinge-iot-im-gesundheitswesen\/","url_meta":{"origin":10604,"position":3},"title":"Internet der Dinge (IoT) im Gesundheitswesen","author":"Prof. Dr. Christian Johner","date":"12. April 2017","format":false,"excerpt":"Beim Internet der Dinge (engl. \"Internet of Things\" kurz IoT) geht es um die digitale Vernetzung von physischen Objekten (\u201ethings\u201c) \u00fcber das Internet (bzw. Internet-Technologien) mit dem Ziel, Prozesse zu automatisieren und zu optimieren. Von den Chancen, die das Internet der Dinge (IoT) erm\u00f6glicht, m\u00f6chte auch das Gesundheitswesen bzw. die\u2026","rel":"","context":"In &quot;Gesundheitswesen &amp; Health IT&quot;","block_context":{"text":"Gesundheitswesen &amp; Health IT","link":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},"img":{"alt_text":"IoT im Gesundheitswesen: Anwendungsbeispiele","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2017\/04\/IoT-Gesundheitswesen-Anwendungen.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2017\/04\/IoT-Gesundheitswesen-Anwendungen.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2017\/04\/IoT-Gesundheitswesen-Anwendungen.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2017\/04\/IoT-Gesundheitswesen-Anwendungen.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2017\/04\/IoT-Gesundheitswesen-Anwendungen.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2017\/04\/IoT-Gesundheitswesen-Anwendungen.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":12195,"url":"https:\/\/www.johner-institut.de\/blog\/iso-14971-risikomanagement\/icf-international-classification-functioning-disability-health\/","url_meta":{"origin":10604,"position":4},"title":"ICF: Wie Ihnen diese Klassifizierung im Risikomanagement n\u00fctzt","author":"Christian Rosenzweig","date":"17. November 2015","format":false,"excerpt":"Die WHO gibt die \u201eInternational Classification of Functioning, Disability and Health\u201c (ICF) heraus, das DIMDI die deutsche Ausgabe, die \u201eInternationale Klassifikation der Funktionsf\u00e4higkeit, Behinderung und Gesundheit\u201c. \u00a0Inhalts\u00fcbersicht Ziel der ICF \u00bb Aufbau der ICF \u00bb ICF im Risikomanagement \u00bb ICF und IEC 62304 \u00bb Diese Taxonomie ist nicht nur im\u2026","rel":"","context":"In &quot;Gesundheitswesen &amp; Health IT&quot;","block_context":{"text":"Gesundheitswesen &amp; Health IT","link":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},"img":{"alt_text":"ICF: Deckblatt der Internationale Klassifikation von Funktionsf\u00e4higkeit Behinderung und Gesundheit","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/12\/ICF-Internationale-Klassifikation-Funktionsfaehigkeit-Behinderung-Gesundheit-300x262.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":4415,"url":"https:\/\/www.johner-institut.de\/blog\/gesundheitswesen\/it-netzwerke-risikomanagement\/","url_meta":{"origin":10604,"position":5},"title":"IT-Netzwerke: Besonderheiten bei Krankenh\u00e4usern","author":"Christian Rosenzweig","date":"9. Juni 2015","format":false,"excerpt":"IT-Netzwerke in Krankenh\u00e4usern unterscheiden sich -- auch wenn die verwendeten Produkte und Technologien die gleichen sind -- von\u00a0IT-Netzwerken in anderen Branchen: Risiken: Von den IT-Netzwerken im Krankenhaus h\u00e4ngen regelm\u00e4\u00dfig Menschenleben ab. Regularien: Entsprechend verlangen Gesetze und Normen wie die IEC 80001 ein\u00a0professionelles Risikomanagement\u00a0speziell f\u00fcr \u00fcber IT-Netzwerke verbundene Medizinprodukte. Budgets: Im\u2026","rel":"","context":"In &quot;Gesundheitswesen &amp; Health IT&quot;","block_context":{"text":"Gesundheitswesen &amp; Health IT","link":"https:\/\/www.johner-institut.de\/blog\/category\/gesundheitswesen\/"},"img":{"alt_text":"IEC 80001","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/03\/IEC-80001.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/03\/IEC-80001.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/03\/IEC-80001.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_shortlink":"https:\/\/wp.me\/pavawf-2L2","jetpack_sharing_enabled":true,"authors":[{"term_id":1210,"user_id":1,"is_guest":0,"slug":"christian","display_name":"Prof. Dr. Christian Johner","avatar_url":{"url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/Christian_Johner.jpg","url2x":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/Christian_Johner.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":"","9":""}],"_links":{"self":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/10604","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/comments?post=10604"}],"version-history":[{"count":1,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/10604\/revisions"}],"predecessor-version":[{"id":1196580,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/10604\/revisions\/1196580"}],"wp:attachment":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/media?parent=10604"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/categories?post=10604"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/tags?post=10604"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/ppma_author?post=10604"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}