{"id":5366385,"date":"2025-10-02T11:33:33","date_gmt":"2025-10-02T09:33:33","guid":{"rendered":"https:\/\/www.johner-institut.de\/blog\/?p=5366385"},"modified":"2026-02-13T08:47:03","modified_gmt":"2026-02-13T07:47:03","slug":"estar-program-fda","status":"publish","type":"post","link":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/","title":{"rendered":"eStar-Programm der FDA: Sollten Sie teilnehmen oder m\u00fcssen Sie?"},"content":{"rendered":"\n<p>Mit dem <strong>eStar-Programm<\/strong> m\u00f6chte die FDA die Effizienz von Zulassungsverfahren (z. B. der 510(k)-Verfahren) durch Digitalisierung erh\u00f6hen. Bei der Weiterentwicklung von eStar arbeitet das Johner Institut mit der FDA  zusammen.<\/p>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex\">\n<p><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-admin\/edit.php?post_type=post\"><\/a>Wie zukunftsweisend dieser Ansatz ist und ob Sie daran teilnehmen sollten oder gar m\u00fcssen, erfahren Sie in diesem Artikel.<\/p>\n<\/div>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\">1. Was ist das eStar-Programm?<\/h2>\n\n\n\n<p>Das eStar-Programm erm\u00f6glicht Medizinprodukteherstellern, ihre Zulassungsunterlagen \u00fcber ein interaktives PDF bei der FDA einzureichen.<\/p>\n\n\n\n<div class=\"jig_defbox\"><div class=\"jig_defbox-definition\"><div class=\"jig_defbox-icon-wrapper\" style=\"fill:#919191\"><svg viewBox=\"0 0 576 512\" width=\"24\" height=\"24\" class=\"dashicons\" aria-hidden=\"true\"><path d=\"M569.5,440c18.5,32-4.7,72-41.6,72H48.1c-36.9,0-60-40.1-41.6-72L246.4,24c18.5-32,64.7-32,83.2,0L569.5,440 L569.5,440z M288,354c-25.4,0-46,20.6-46,46s20.6,46,46,46s46-20.6,46-46S313.4,354,288,354z M244.3,188.7l7.4,136 c0.3,6.4,5.6,11.3,12,11.3h48.5c6.4,0,11.6-5,12-11.3l7.4-136c0.4-6.9-5.1-12.7-12-12.7h-63.4C249.4,176,244,181.8,244.3,188.7 L244.3,188.7z\"><\/path><\/svg><\/div><span class=\"jig_defbox-header\" style=\"color:#919191\">Achtung!<\/span><\/div>\n<p>Die FDA schreibt in ihrem finalisierten Guidance-Dokument <a href=\"https:\/\/www.fda.gov\/media\/152429\/download\">Electronic Submission Template for Medical Device 510(k) Submissions<\/a>, dass sie seit dem 01.10.2023 510(k)-Einreichungen nur noch im eSTAR-Format und per Upload \u00fcber das FDA-Portal akzeptiert.<\/p>\n\n\n\n<p>\u00c4hnliches gilt f\u00fcr De-Novo-Einreichungen. Diese werden gem\u00e4\u00df dem Guidance-Dokument <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/electronic-submission-template-medical-device-de-novo-requests\">Electronic Submission Template for Medical Device De Novo Requests<\/a> ab dem 01.10.2025 ebenfalls nur noch im eSTAR-Format akzeptiert. Dieses erg\u00e4nzt die De-Novo-spezifischen Angaben wie Classification, Performance Testing, Benefit-Risk-Analysis und Mitigation Measures.<\/p>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">a) Interaktivit\u00e4t<\/h3>\n\n\n\n<p>Die Interaktivit\u00e4t hat mehrere Aspekte.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Integrierte Fehlerpr\u00fcfung<\/h4>\n\n\n\n<p>Das PDF markiert Bereiche, in denen Daten offensichtlich noch Fehler enthalten, in Rot, und korrekte Bereiche in Gr\u00fcn (s. Abb. 1).<\/p>\n\n\n\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1.png\" data-rel=\"lightbox-image-0\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"214\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-300x214.png\" alt=\"Das PDF markiert farblich, ob Informationen fehlen (rot) oder vorhanden sind. Das Dokument blendet Bereiche wie den zur Software ein, wenn wie in diesem Beispiel der Hersteller angibt, dass sein Produkt Software enth\u00e4lt.\" class=\"wp-image-5366390\" srcset=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-300x214.png 300w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-1024x729.png 1024w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-768x547.png 768w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-200x142.png 200w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-400x285.png 400w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-600x427.png 600w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-800x569.png 800w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-1200x854.png 1200w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1.png 1280w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption class=\"wp-element-caption\">Abb. 1: Im PDF wird farblich markiert, ob Informationen fehlen (rot) oder vorhanden sind (gr\u00fcn). Wenn wie in diesem Beispiel der Hersteller angibt, dass sein Produkt Software enth\u00e4lt, werden die entsprechenden Bereiche eingeblendet. <\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Automatisiertes Ein- und Ausblenden von Bereichen<\/h4>\n\n\n\n<p>Das interaktive Dokument blendet Bereiche ein oder aus, abh\u00e4ngig von der Auswahl. Beispielsweise zeigt das Dokument automatisch Details zu den Software-Unterlagen, wenn man ausw\u00e4hlt, dass das Produkt Software enth\u00e4lt oder eine Standalone-Software ist (s. Abb. 1). Diese Logik zum Ein- und Ausblenden legt die FDA in Schematron-Dateien fest (s. Abb. 2).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron.jpg\" data-rel=\"lightbox-image-1\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"245\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron-1024x245.jpg\" alt=\"Ausschnit aus einer der Schematron-Datei der FDA f\u00fcr das eStar-Programm\" class=\"wp-image-5379191\" style=\"width:840px;height:auto\" srcset=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron-1024x245.jpg 1024w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron-300x72.jpg 300w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron-768x184.jpg 768w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron-1536x368.jpg 1536w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/09\/eStar-Schematron.jpg 1600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Abb. 2: Ausschnitt aus einer Schematron-Datei der FDA f\u00fcr das eStar-Programm.<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Integration von Anh\u00e4ngen<\/h4>\n\n\n\n<p>Das PDF erlaubt es, Anh\u00e4nge beizuf\u00fcgen. Aus Sicht der FDA m\u00fcssen diese Anh\u00e4nge sogar beigef\u00fcgt werden. Dabei gibt es keine Einschr\u00e4nkung des Datenformats. Einzig die Gr\u00f6\u00dfe des resultierenden PDF-Dokuments ist auf 1 GB beschr\u00e4nkt (s. Abb. 3).<\/p>\n\n\n\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments.jpeg\" data-rel=\"lightbox-image-2\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"53\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-300x53.jpeg\" alt=\"Das &quot;eStar Program&quot; verlangt, Anh\u00e4nge in das PDF zu integrieren.\" class=\"wp-image-5366389\" srcset=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-300x53.jpeg 300w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-1024x181.jpeg 1024w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-768x135.jpeg 768w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-200x35.jpeg 200w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-400x71.jpeg 400w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-600x106.jpeg 600w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments-800x141.jpeg 800w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Attachments.jpeg 1055w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><figcaption class=\"wp-element-caption\">Abb. 3: Das eStar-Programm erm\u00f6glicht es, Anh\u00e4nge in das PDF zu integrieren.<\/figcaption><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">M\u00f6glichkeiten zum Import und Export<\/h4>\n\n\n\n<p>Alle Daten, mit Ausnahme der Anh\u00e4nge, k\u00f6nnen \u00fcber das PDF aus XML importiert und nach XML exportiert werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">b) Elektronische Einreichung<\/h3>\n\n\n\n<p>Inzwischen erfolgt die Einreichung nicht mehr auf einem physischen Datentr\u00e4ger, sondern elektronisch. Abh\u00e4ngig vom zust\u00e4ndigen FDA Center reichen Hersteller \u00fcber das <a href=\"https:\/\/www.fda.gov\/medical-devices\/industry-medical-devices\/send-and-track-medical-device-premarket-submissions-online-cdrh-portal\">CDRH Portal <\/a>ein oder \u00fcber das <a href=\"https:\/\/www.fda.gov\/about-fda\/center-biologics-evaluation-and-research-cber\/regulatory-submissions-electronic-and-paper-format-cber-regulated-products\">ESG Gateway<\/a> bei CBER-bezogenen Einreichungen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">c) eStar versus eCopy<\/h3>\n\n\n\n<p>Tats\u00e4chlich stellt das eStar-Programm nach dem eCopy\/eSubmitter-Programm die n\u00e4chste Evolutionsstufe in der Digitalisierung dar. Bei dem eCopy\/eSubmitter-Programm gab die FDA \u201enur\u201c die Formatierung der elektronischen Einreichungsakte vor, an die sich die Hersteller halten m\u00fcssen. Eine vorgegebene Struktur der Dokumente selbst oder gar strukturierte Daten wie beim eStar-Programm gibt es beim eCopy\/eSubmitter-Programm nicht.<\/p>\n\n\n\n<div class=\"jig_defbox\"><div class=\"jig_defbox-definition\"><div class=\"jig_defbox-icon-wrapper\" style=\"fill:#919191\"><svg viewBox=\"0 0 48 48\" width=\"24\" height=\"24\" class=\"dashicons\" aria-hidden=\"true\"><g><path d=\"M20,19.5h16v-3H20V19.5z M20,25.5h16v-3H20V25.5z M20,31.5h10v-3H20V31.5z M14.1,20c0.6,0,1-0.2,1.4-0.6 c0.4-0.4,0.6-0.9,0.6-1.4s-0.2-1-0.6-1.4c-0.4-0.4-0.9-0.6-1.4-0.6c-0.6,0-1,0.2-1.4,0.6c-0.4,0.4-0.6,0.9-0.6,1.4 c0,0.6,0.2,1,0.6,1.4C13,19.9,13.5,20,14.1,20z M14.1,26c0.6,0,1-0.2,1.4-0.6c0.4-0.4,0.6-0.9,0.6-1.4c0-0.6-0.2-1-0.6-1.4 S14.6,22,14.1,22c-0.6,0-1,0.2-1.4,0.6s-0.6,0.9-0.6,1.4c0,0.6,0.2,1,0.6,1.4S13.5,26,14.1,26z M14.1,32c0.6,0,1-0.2,1.4-0.6 c0.4-0.4,0.6-0.9,0.6-1.4c0-0.6-0.2-1-0.6-1.4c-0.4-0.4-0.9-0.6-1.4-0.6c-0.6,0-1,0.2-1.4,0.6s-0.6,0.9-0.6,1.4 c0,0.6,0.2,1,0.6,1.4S13.5,32,14.1,32z M7,40c-1.7,0-3-1.4-3-3V11c0-0.8,0.3-1.5,0.9-2.1C5.5,8.3,6.2,8,7,8h34 c0.8,0,1.5,0.3,2.1,0.9C43.7,9.5,44,10.2,44,11v26c0,0.8-0.3,1.5-0.9,2.1C42.5,39.7,41.8,40,41,40L7,40z M7,37h34V11H7V37z M7,11\"><\/path><\/g><\/svg><\/div><span class=\"jig_defbox-header\" style=\"color:#919191\">Weiterf\u00fchrende Informationen<\/span><\/div>\n<p>Wenn Sie mehr zur Geschichte dieser beiden Programme wissen wollen und einen Vergleich w\u00fcnschen, empfiehlt sich ein Blick in dieses <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/electronic-submission-template-medical-device-510k-submissions\">Guidance-Dokument<\/a>.<\/p>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">2. Wer kann oder darf das eStar-Programm nutzen?<\/h2>\n\n\n\n<p>Offensichtlich soll das eStar-Programm die Medizinproduktehersteller dabei unterst\u00fctzen, Zulassungsunterlagen schneller und in besserer G\u00fcte zusammenzustellen und einzureichen. Doch es wendet sich nicht an alle Hersteller und eignet sich nicht f\u00fcr alle Zulassungsverfahren.<\/p>\n\n\n\n<p>Das eStar-Programm ist nur anwendbar f\u00fcr:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.johner-institut.de\/blog\/tag\/510k\/\">510(k)-Zulassungsverfahren<\/a> (traditional, <a href=\"https:\/\/www.johner-institut.de\/blog\/fda\/abbreviated-510k\/\">abbreviated<\/a>, <a href=\"https:\/\/www.johner-institut.de\/blog\/fda\/special-510k\/\">special<\/a>)<\/li>\n\n\n\n<li><a href=\"https:\/\/www.johner-institut.de\/blog\/fda\/de-novo-program-der-fda\/\">De-Novo-Zulassungsverfahren<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/fda-pre-submission-programm\/\">Pre-Submissions<\/a><\/li>\n\n\n\n<li>Medizinprodukte, IVD und Kombinationsprodukte<\/li>\n\n\n\n<li>Gewisse PMA-Zulassungsverfahren (Original, PMA Panel Track Supplements, PMA Real-Time, PMA 180 Day Supplements)<\/li>\n<\/ul>\n\n\n\n<div class=\"jig_defbox\"><div class=\"jig_defbox-definition\"><div class=\"jig_defbox-icon-wrapper\" style=\"fill:#919191\"><svg viewBox=\"0 0 512 512\" width=\"24\" height=\"24\" class=\"dashicons\" aria-hidden=\"true\"><g><path d=\"M430.9,177.6c-0.3-96-78.1-174.1-174-174.9c-0.1,0-0.2,0-0.4,0c-0.2,0-0.4,0-0.5,0c-0.2,0-0.4,0-0.5,0 c-0.1,0-0.2,0-0.4,0c-95.9,0.8-173.7,78.9-174,174.9c-0.4,7.3-1.9,60.3,36.6,109.2c29.5,37.6,49.4,74.7,55,85.9v63.5 c0,0,0,0.1,0,0.1c0,0.5,0,0.9,0.1,1.4c0,0.3,0.1,0.6,0.1,0.9c0,0.1,0,0.2,0,0.2c0.4,2.7,1.4,5.2,3,7.4l33.7,55.1 c3.1,5.1,8.7,8.2,14.7,8.2h61.8c6,0,11.5-3.1,14.7-8.2l33.7-55.1c1.5-2.1,2.6-4.6,3-7.4c0-0.1,0-0.2,0-0.2c0-0.3,0.1-0.6,0.1-0.9 c0-0.5,0.1-0.9,0.1-1.4c0,0,0-0.1,0-0.1v-60.3c1.2-2.4,22.3-45.5,56.7-89.2C432.8,237.8,431.3,184.9,430.9,177.6z M303.3,418.8 h-96.2v-33.1h96.2V418.8z M276.4,475h-42.5l-13.3-21.6h69L276.4,475z M311.6,351.4H200.4c-8.6-16.3-28-50.6-55.7-85.9 c-32-40.6-29.3-85.7-29.3-86c0-0.4,0.1-0.9,0.1-1.3c0-77.6,63-140.8,140.5-141.1c77.5,0.3,140.5,63.5,140.5,141.1 c0,0.4,0,0.9,0.1,1.3c0,0.4,3.1,44.9-29.3,86C339.5,300.8,320.2,335.1,311.6,351.4z\"><\/path><path d=\"M257.8,64.4c-62,0-112.5,50.5-112.5,112.5c0,9.5,7.7,17.2,17.2,17.2s17.2-7.7,17.2-17.2 c0-43.1,35-78.1,78.1-78.1c9.5,0,17.2-7.7,17.2-17.2S267.3,64.4,257.8,64.4z\"><\/path><\/g><\/svg><\/div><span class=\"jig_defbox-header\" style=\"color:#919191\">Hinweis!<\/span><\/div>\n<p>Die Teilnahme am eStar-Programm ist explizit freiwillig. Hersteller und Produkte, f\u00fcr die das Verfahren anwendbar ist, d\u00fcrfen, aber m\u00fcssen nicht daran teilnehmen.<\/p>\n\n\n\n<p>Ausgenommen sind 510(k)-Verfahren. Hier ist die Teilnahme am eStar-Programm Pflicht.<\/p>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">3. Wie hilft das eStar-Programm?<\/h2>\n\n\n\n<p>Das eStar-Programm n\u00fctzt den Herstellern ebenso wie der FDA.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">a) Unterlagen in besserer G\u00fcte<\/h3>\n\n\n\n<p>Die FDA erh\u00e4lt die Unterlagen in h\u00f6herer G\u00fcte, weil das PDF den Herstellern hilft, offensichtliche Fehler wie fehlende Informationen oder Tippfehler (z. B. bei Produkt-Codes) zu vermeiden. Dazu tragen beispielsweise Drop-Down-Listen und \u00dcberpr\u00fcfungen der Inhalte auf Vollst\u00e4ndigkeit und Konsistenz bei.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">b) Mehr Sicherheit<\/h3>\n\n\n\n<p>Das PDF verifiziert markiert unvollst\u00e4ndige oder fehlende Informationen sowohl auf Ebene des einzelnen Datums als auch auf Ebene des gesamten Dokuments (s. Abb. 4).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification.jpeg\" data-rel=\"lightbox-image-3\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"351\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-1024x351.jpeg\" alt=\"Das PDF enth\u00e4lt eine \u00dcbersicht \u00fcber die Ergebnisse der automatisierten Verifikation.\" class=\"wp-image-5366394\" srcset=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-1024x351.jpeg 1024w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-300x103.jpeg 300w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-768x263.jpeg 768w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-200x68.jpeg 200w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-400x137.jpeg 400w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-600x205.jpeg 600w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-800x274.jpeg 800w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification.jpeg 1142w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Abb. 4: Das PDF enth\u00e4lt eine \u00dcbersicht \u00fcber die Ergebnisse der automatisierten Verifikation.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">c) Geringerer Aufwand<\/h3>\n\n\n\n<p>Die Hersteller und die FDA ersparen sich die <a href=\"https:\/\/www.johner-institut.de\/blog\/fda\/fda-refuse-to-accept-policy\/\">RTA<\/a>-Korrekturschleife. Der Rest des Prozesses bleibt allerdings unver\u00e4ndert:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>The remainder of a 510(k) review will be conducted according to the FDA guidance, &#8222;<a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/510k-program-evaluating-substantial-equivalence-premarket-notifications-510k\">The 510(k) Program: Evaluating Substantial Equivalence in Premarket Notifications [510(k)]<\/a>,\u201d following the procedures identified in&nbsp;<a href=\"https:\/\/www.ecfr.gov\/current\/title-21\/chapter-I\/subchapter-H\/part-807\/subpart-E\">21 CFR 807 subpart E<\/a>. A De Novo review will be conducted according to the FDA guidance, \u201c<a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/de-novo-classification-process-evaluation-automatic-class-iii-designation\">De Novo Classification Process (Evaluation of Automatic Class III Designation)<\/a>,\u201d following the procedures identified in 21 CFR 860, subpart D.<\/p>\n<\/blockquote>\n\n\n\n<p>Die FDA muss keine Inhalte per Copy-and-paste in die eigenen Systeme \u00fcbergeben. Auch das erspart Aufwand.<\/p>\n\n\n\n<p>Zudem findet die Beh\u00f6rde die Unterlagen schneller, weil der Zugriff auf die Inhalte und Anh\u00e4nge direkt \u00fcber das PDF-Dokument m\u00f6glich ist und weil die Hersteller gezwungen werden, die Anh\u00e4nge in der von der FDA vorgegebenen Struktur zusammenzustellen. Auch dies erspart der Beh\u00f6rde Arbeit. Sie sagt jedoch keine k\u00fcrzeren Bearbeitungsdauern zu.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Bewertung des eStar-Programms<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">a) Positiv<\/h3>\n\n\n\n<p>Die FDA unterst\u00fctzt mit diesem Programm die Hersteller dabei, vollst\u00e4ndige, konsistente und korrekte Unterlagen zusammenzustellen. <\/p>\n\n\n\n<p>Indem sie viele Vorpr\u00fcfungen automatisiert, profitiert auch die Beh\u00f6rde selbst. Das wiederum kommt den Herstellern zugute, weil Zulassungsprozesse schneller ablaufen und insbesondere unn\u00f6tige Iterationsschleifen (inkl. RTA-Pr\u00fcfung) vermieden werden k\u00f6nnen.<\/p>\n\n\n\n<p>Die Struktur des PDF-Dokuments (s. Abb. 5) und die Aufteilung der Anh\u00e4nge gibt den Herstellern wertvolle Anregungen, um die eigenen Unterlagen zu strukturieren. Das gilt sowohl auf Ebene der Verzeichnisse als auch f\u00fcr die Dokumente selbst.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Struktur.jpeg\" data-rel=\"lightbox-image-4\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" decoding=\"async\" width=\"454\" height=\"694\" src=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Struktur.jpeg\" alt=\"Das PDF l\u00e4sst die Struktur erkennen, die Hersteller als Anregung nutzen k\u00f6nnen, um die eigene Dokumentation zu strukturieren.\" class=\"wp-image-5366395\" srcset=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Struktur.jpeg 454w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Struktur-196x300.jpeg 196w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Struktur-200x306.jpeg 200w, https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Struktur-400x611.jpeg 400w\" sizes=\"auto, (max-width: 454px) 100vw, 454px\" \/><\/a><figcaption class=\"wp-element-caption\">Abb. 5: Das PDF zeigt die Struktur, die Hersteller f\u00fcr die eigene Dokumentation \u00fcbernehmen k\u00f6nnen.<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">b) Kritik<\/h3>\n\n\n\n<p>Die M\u00f6glichkeit eines XML-Imports kann bestenfalls eine \u00dcbergangstechnologie sein, um die Informationen aus bestehenden Systemen in das PDF-Dokument der FDA zu \u00fcbertragen. Das ist zwar besser als ein manuelles Copy-and-paste, aber kein Ersatz f\u00fcr eine API.<\/p>\n\n\n\n<p>Die FDA gibt die (Struktur der) erwarteten Anh\u00e4nge vor. Damit zwingt sie die Hersteller, ihre Dokumente FDA-spezifisch zusammenzustellen. Dies f\u00fchrt zu den \u00fcblichen Flei\u00dfaufgaben von Regulatory Affairs Managern und Managerinnen. Aufgaben, die eine vollst\u00e4ndige Digitalisierung der Prozesse \u00fcberfl\u00fcssig machen k\u00f6nnte und sollte.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">c) Bewertung und Ausblick<\/h3>\n\n\n\n<p>Die FDA ist mit dem eStar-Programm einen deutlichen Schritt weiter als viele Benannte Stellen mit ihren \u201eApplication Forms\u201c. Diese k\u00f6nnen oft weder von der Funktionalit\u00e4t noch von der Gebrauchstauglichkeit und Interoperabilit\u00e4t (XML-Import und Expert) mithalten.<\/p>\n\n\n\n<p>Das interaktive PDF ist eine Software, die wie jede andere Software validiert und weiterentwickelt werden muss. Bisher erfolgt die Aktualisierung durch die FDA sehr zeitnah. Zum Beispiel ist das <a href=\"https:\/\/www.johner-institut.de\/blog\/iec-62304-medizinische-software\/level-of-concern\/\">neue Guidance-Dokument zu Software <\/a>mit der Unterscheidung nach \u201eBasic Documentation\u201c und \u201eEnhanced Documentation\u201c inzwischen umgesetzt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. Fazit<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">a) Zusammenfassung<\/h3>\n\n\n\n<p>Mit dem eStar-Programm geht die FDA den n\u00e4chsten Schritt bei der Digitalisierung der Zulassungsprozesse. Sie treibt damit das auf die Spitze, was man mit einem dokumenten- und PDF-basierten Ansatz erreichen kann.<\/p>\n\n\n\n<p>Die Interaktivit\u00e4t der PDF-Dokumente mit integrierter Anwendungslogik und einer Mischung aus strukturierten Daten und Anh\u00e4ngen l\u00e4sst erahnen, was mit einer vollst\u00e4ndig automatisierten Erfassung und Pr\u00fcfung von Zulassungsdaten m\u00f6glich w\u00e4re.<\/p>\n\n\n\n<p>Bis dahin m\u00fcssen die Hersteller mit Dokumenten arbeiten und dabei die folgenden Leitlinien beachten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Das <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/providing-regulatory-submissions-medical-devices-electronic-format-submissions-under-section-745ab\">bestehende Guidance-Dokument<\/a> \u201eProviding Regulatory Submissions for Medical Devices in Electronic Format \u2014 Submissions Under Section 745A(b) of the Federal Food, Drug, and Cosmetic Act\u201d, auch wenn dieses nicht mehr ganz aktuell ist, da es vor dem eStar-Programm publiziert wurde und dieses noch nicht enth\u00e4lt.<\/li>\n\n\n\n<li>Wichtiger sind das <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/electronic-submission-template-medical-device-510k-submissions\">neue Guidance-Dokument<\/a> \u201eElectronic Submission Template for Medical Device 510(k) Submissions\u201c und das Guidance-Dokument <a href=\"https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/electronic-submission-template-medical-device-de-novo-requests\" target=\"_blank\" rel=\"noreferrer noopener\">Electronic Submission Template for Medical Device De Novo Requests.<\/a><\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Das Johner Institut unterst\u00fctzt Hersteller und Benannte Stellen bei der digitalen Transformation.&nbsp;Interesse? Dann nehmen Sie gleich <a href=\"https:\/\/www.johner-institut.de\/kontakt\/\">Kontakt<\/a> auf!<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p>Versionshistorie:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2025-10-02: In Hinweis-Box zu Beginn einen Satz zu den \u201eDe-Novo-Inhalten\u201c erg\u00e4nzt.<\/li>\n\n\n\n<li>2024-10-15: Hinweis zur verpflichtenden Nutzung von eSTAR f\u00fcr De Novo Requests ab dem 01.10.2025 erg\u00e4nzt<\/li>\n\n\n\n<li>2024-08-20: Bewertungen in das neue Kapitel 4 verschoben. Nummerierung konsequent umgesetzt. Einleitung erg\u00e4nzt. Kapitel 1.a) neu strukturiert und um Bild der Schematron-Datei (Abb. 2) erg\u00e4nzt.<\/li>\n\n\n\n<li>2023-09-15: Hinweise zur elektronischen Einreichung und Verf\u00fcgbarkeit von eSTAR f\u00fcr Kombinationsprodukte erg\u00e4nzt<\/li>\n\n\n\n<li>2022-09-23: Hinweise zum neuen eSTAR-Guidance-Dokument erg\u00e4nzt<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Mit dem eStar-Programm m\u00f6chte die FDA die Effizienz von Zulassungsverfahren (z. B. der 510(k)-Verfahren) durch Digitalisierung erh\u00f6hen. Bei der Weiterentwicklung von eStar arbeitet das Johner Institut mit der FDA zusammen. Wie zukunftsweisend dieser Ansatz ist und ob Sie daran teilnehmen sollten oder gar m\u00fcssen, erfahren Sie in diesem Artikel.<\/p>\n","protected":false},"author":110,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[1108],"tags":[1197,1194],"ppma_author":[1251],"class_list":["post-5366385","post","type-post","status-publish","format-standard","hentry","category-regulatory-affairs","tag-internationale-zulassung","tag-management","category-1108","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Das eStar-Programm der FDA - Pflicht oder Chance?<\/title>\n<meta name=\"description\" content=\"Die FDA geht mit dem eStar-Programm den n\u00e4chsten Schritt der Digitalisierung. Doch welche Hersteller profitieren davon? Antworten hier!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Das eStar-Programm der FDA - Pflicht oder Chance?\" \/>\n<meta property=\"og:description\" content=\"Die FDA geht mit dem eStar-Programm den n\u00e4chsten Schritt der Digitalisierung. Doch welche Hersteller profitieren davon? Antworten hier!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/\" \/>\n<meta property=\"og:site_name\" content=\"Regulatorisches Wissen f\u00fcr Medizinprodukte\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/JohnerInstitut\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-02T09:33:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-13T07:47:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"911\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Katharina Keutgen\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Katharina Keutgen\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/\"},\"author\":{\"name\":\"Katharina Keutgen\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/person\\\/0b129d2f3bce139c0cca32b2f219f636\"},\"headline\":\"eStar-Programm der FDA: Sollten Sie teilnehmen oder m\u00fcssen Sie?\",\"datePublished\":\"2025-10-02T09:33:33+00:00\",\"dateModified\":\"2026-02-13T07:47:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/\"},\"wordCount\":1414,\"commentCount\":4,\"publisher\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/eStar-Program-Verification-internal-1-300x214.png\",\"keywords\":[\"Internationale Zulassung von Medizinprodukten\",\"Unterst\u00fctzung f\u00fcr Management und F\u00fchrungskr\u00e4fte\"],\"articleSection\":[\"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/\",\"name\":\"Das eStar-Programm der FDA - Pflicht oder Chance?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/eStar-Program-Verification-internal-1-300x214.png\",\"datePublished\":\"2025-10-02T09:33:33+00:00\",\"dateModified\":\"2026-02-13T07:47:03+00:00\",\"description\":\"Die FDA geht mit dem eStar-Programm den n\u00e4chsten Schritt der Digitalisierung. Doch welche Hersteller profitieren davon? Antworten hier!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/eStar-Program-Verification-internal-1.png\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/09\\\/eStar-Program-Verification-internal-1.png\",\"width\":1280,\"height\":911},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/regulatory-affairs\\\/estar-program-fda\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte\",\"item\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/category\\\/regulatory-affairs\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"eStar-Programm der FDA: Sollten Sie teilnehmen oder m\u00fcssen Sie?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\",\"name\":\"Regulatorisches Wissen f\u00fcr Medizinprodukte\",\"description\":\"Fachartikel zur Entwicklung und Zulassung von Medizinprodukten und weiteren regulatorischen Themen\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\",\"name\":\"Johner Institut GmbH\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/07\\\/Johner-Institut.png\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/07\\\/Johner-Institut.png\",\"width\":1213,\"height\":286,\"caption\":\"Johner Institut GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/JohnerInstitut\\\/\",\"https:\\\/\\\/x.com\\\/christianjohner\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/JohnerInstitut\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/person\\\/0b129d2f3bce139c0cca32b2f219f636\",\"name\":\"Katharina Keutgen\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/Katharina_Keutgen_300x300.png487b238417c0b1ededf20a3377432d12\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/Katharina_Keutgen_300x300.png\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/05\\\/Katharina_Keutgen_300x300.png\",\"caption\":\"Katharina Keutgen\"},\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/author\\\/katharina-keutgen\\\/\"}]}<\/script>\n<meta name=\"copyright\" content=\"Johner Institut GmbH\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Das eStar-Programm der FDA - Pflicht oder Chance?","description":"Die FDA geht mit dem eStar-Programm den n\u00e4chsten Schritt der Digitalisierung. Doch welche Hersteller profitieren davon? Antworten hier!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/","og_locale":"de_DE","og_type":"article","og_title":"Das eStar-Programm der FDA - Pflicht oder Chance?","og_description":"Die FDA geht mit dem eStar-Programm den n\u00e4chsten Schritt der Digitalisierung. Doch welche Hersteller profitieren davon? Antworten hier!","og_url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/","og_site_name":"Regulatorisches Wissen f\u00fcr Medizinprodukte","article_publisher":"https:\/\/www.facebook.com\/JohnerInstitut\/","article_published_time":"2025-10-02T09:33:33+00:00","article_modified_time":"2026-02-13T07:47:03+00:00","og_image":[{"width":1280,"height":911,"url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1.png","type":"image\/png"}],"author":"Katharina Keutgen","twitter_misc":{"Verfasst von":"Katharina Keutgen","Gesch\u00e4tzte Lesezeit":"8\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#article","isPartOf":{"@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/"},"author":{"name":"Katharina Keutgen","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/person\/0b129d2f3bce139c0cca32b2f219f636"},"headline":"eStar-Programm der FDA: Sollten Sie teilnehmen oder m\u00fcssen Sie?","datePublished":"2025-10-02T09:33:33+00:00","dateModified":"2026-02-13T07:47:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/"},"wordCount":1414,"commentCount":4,"publisher":{"@id":"https:\/\/www.johner-institut.de\/blog\/#organization"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#primaryimage"},"thumbnailUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-300x214.png","keywords":["Internationale Zulassung von Medizinprodukten","Unterst\u00fctzung f\u00fcr Management und F\u00fchrungskr\u00e4fte"],"articleSection":["Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/","url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/","name":"Das eStar-Programm der FDA - Pflicht oder Chance?","isPartOf":{"@id":"https:\/\/www.johner-institut.de\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#primaryimage"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#primaryimage"},"thumbnailUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1-300x214.png","datePublished":"2025-10-02T09:33:33+00:00","dateModified":"2026-02-13T07:47:03+00:00","description":"Die FDA geht mit dem eStar-Programm den n\u00e4chsten Schritt der Digitalisierung. Doch welche Hersteller profitieren davon? Antworten hier!","breadcrumb":{"@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#primaryimage","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1.png","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2022\/09\/eStar-Program-Verification-internal-1.png","width":1280,"height":911},{"@type":"BreadcrumbList","@id":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/estar-program-fda\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Blog","item":"https:\/\/www.johner-institut.de\/blog\/"},{"@type":"ListItem","position":2,"name":"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte","item":"https:\/\/www.johner-institut.de\/blog\/category\/regulatory-affairs\/"},{"@type":"ListItem","position":3,"name":"eStar-Programm der FDA: Sollten Sie teilnehmen oder m\u00fcssen Sie?"}]},{"@type":"WebSite","@id":"https:\/\/www.johner-institut.de\/blog\/#website","url":"https:\/\/www.johner-institut.de\/blog\/","name":"Regulatorisches Wissen f\u00fcr Medizinprodukte","description":"Fachartikel zur Entwicklung und Zulassung von Medizinprodukten und weiteren regulatorischen Themen","publisher":{"@id":"https:\/\/www.johner-institut.de\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.johner-institut.de\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.johner-institut.de\/blog\/#organization","name":"Johner Institut GmbH","url":"https:\/\/www.johner-institut.de\/blog\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/07\/Johner-Institut.png","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/07\/Johner-Institut.png","width":1213,"height":286,"caption":"Johner Institut GmbH"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/JohnerInstitut\/","https:\/\/x.com\/christianjohner","https:\/\/www.youtube.com\/user\/JohnerInstitut"]},{"@type":"Person","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/person\/0b129d2f3bce139c0cca32b2f219f636","name":"Katharina Keutgen","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/05\/Katharina_Keutgen_300x300.png487b238417c0b1ededf20a3377432d12","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/05\/Katharina_Keutgen_300x300.png","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/05\/Katharina_Keutgen_300x300.png","caption":"Katharina Keutgen"},"url":"https:\/\/www.johner-institut.de\/blog\/author\/katharina-keutgen\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack-related-posts":[{"id":5374121,"url":"https:\/\/www.johner-institut.de\/blog\/systems-engineering\/asca\/","url_meta":{"origin":5366385,"position":0},"title":"ASCA: Accreditation Scheme for Conformity Assessment","author":"Mario Klessascheck","date":"17. Oktober 2025","format":false,"excerpt":"ASCA steht f\u00fcr Accreditation Scheme for Conformity Assessment. Das Verfahren soll Konformit\u00e4tsbewertungen und damit Zulassungsverfahren beschleunigen. Es ist aber weder bei allen Produkten noch bei allen M\u00e4rkten anwendbar. Wer von ASCA profitiert und wie das Verfahren abl\u00e4uft, erl\u00e4utert dieser Artikel. 1. ASCA \u2013 Die Grundlagen a) Wen betrifft ASCA? ASCA\u2026","rel":"","context":"In &quot;Systems Engineering bei Medizinprodukten&quot;","block_context":{"text":"Systems Engineering bei Medizinprodukten","link":"https:\/\/www.johner-institut.de\/blog\/category\/systems-engineering\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/ASCA.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/ASCA.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/ASCA.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/ASCA.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/ASCA.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1391222,"url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/fda-pre-submission-programm\/","url_meta":{"origin":5366385,"position":1},"title":"FDA Pre-Submission-Programm","author":"Katharina Keutgen","date":"16. Oktober 2024","format":false,"excerpt":"Mit dem\u00a0Pre-Submission-Programm\u00a0(kurz \u201ePre-Sub\u201c) bietet die FDA ein formales Verfahren an, mit dem Hersteller bereits vor der eigentlichen Zulassung ihre Zulassungsstrategie sowie konkrete Fragen kl\u00e4ren k\u00f6nnen. Ein Pre-Sub Request eignet sich unter anderem im Vorfeld von 510(k)s, De Novo Requests oder auch PMAs. Damit k\u00f6nnen auf beiden Seiten unn\u00f6tige Kosten und\u2026","rel":"","context":"In &quot;Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte&quot;","block_context":{"text":"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte","link":"https:\/\/www.johner-institut.de\/blog\/category\/regulatory-affairs\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/09\/Q-Submission-Typen-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/09\/Q-Submission-Typen-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/09\/Q-Submission-Typen-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/09\/Q-Submission-Typen-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/09\/Q-Submission-Typen-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1669275,"url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/breakthrough-devices\/","url_meta":{"origin":5366385,"position":2},"title":"Breakthrough Devices Program der FDA","author":"Margret Seidenfaden","date":"25. Februar 2024","format":false,"excerpt":"Das Breakthrough Devices Program ist ein Zulassungsverfahren f\u00fcr Medizinprodukten, mit dem die FDA schwerstkranken Patienten einen schnelleren Zugang zu neuartigen Medizinprodukten erm\u00f6glichen m\u00f6chte. Die Beh\u00f6rde hat dazu im Dezember 2018 ein \u201eGuidance Document\u201c ver\u00f6ffentlicht. Sie erfahren in diesem Artikel, wie das \u201eBreakthrough Devices Program\u201c abl\u00e4uft und welche Voraussetzungen die Hersteller\u2026","rel":"","context":"In &quot;Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte&quot;","block_context":{"text":"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte","link":"https:\/\/www.johner-institut.de\/blog\/category\/regulatory-affairs\/"},"img":{"alt_text":"Das Breakthrough Devices Program der FDA beschleunigt die Zulassung","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2019\/01\/Breakthrough-Devices.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":12518,"url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/ecopy-esubmission\/","url_meta":{"origin":5366385,"position":3},"title":"eCopy-Programm der FDA","author":"Luca Salvatore","date":"18. November 2024","format":false,"excerpt":"Unter eCopy versteht die FDA die elektronische Kopie\/Version von papierbasierten Einreichungen, z. B. im Rahmen einer 510(k)-Submission. Umstellung auf eSTAR Die FDA hat ihr Einreichungsformat inzwischen fast vollst\u00e4ndig auf eSTAR umgestellt. F\u00fcr Verfahren wie das 510(k) ist eSTAR inzwischen sogar verpflichtend zu nutzen. Somit wird eCopy in den kommenden Jahren\u2026","rel":"","context":"In &quot;Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte&quot;","block_context":{"text":"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte","link":"https:\/\/www.johner-institut.de\/blog\/category\/regulatory-affairs\/"},"img":{"alt_text":"ecopy, esubmission auf physichem Medium","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2016\/01\/ecopy-e-submission-usb-300x181.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":2692873,"url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/safer-technologies-program-step\/","url_meta":{"origin":5366385,"position":4},"title":"Safer Technologies Program (STeP): Schneller in den US-Markt?","author":"Prof. Dr. Christian Johner","date":"24. September 2019","format":false,"excerpt":"Mit dem Safer Technologies Program (STeP) m\u00f6chte die FDA Herstellern innovativer Medizinprodukte einen neuen Zulassungsweg bahnen. Damit verfolgt die Beh\u00f6rde das Ziel, dass Patienten schneller von diesen Innovationen profitieren. Lesen Sie in diesem Artikel, welche Vereinfachungen und Hilfestellungen die FDA f\u00fcr Sie als Hersteller vorsieht und welche Voraussetzungen Sie erf\u00fcllen\u2026","rel":"","context":"In &quot;Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte&quot;","block_context":{"text":"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte","link":"https:\/\/www.johner-institut.de\/blog\/category\/regulatory-affairs\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2019\/09\/Safer-Technologies-Program-STeP-FDA.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2019\/09\/Safer-Technologies-Program-STeP-FDA.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2019\/09\/Safer-Technologies-Program-STeP-FDA.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2019\/09\/Safer-Technologies-Program-STeP-FDA.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2019\/09\/Safer-Technologies-Program-STeP-FDA.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1186059,"url":"https:\/\/www.johner-institut.de\/blog\/regulatory-affairs\/abbreviated-510k\/","url_meta":{"origin":5366385,"position":5},"title":"Abbreviated 510(k) \u2013 Wann die Abk\u00fcrzung erlaubt ist","author":"Margret Seidenfaden","date":"23. September 2019","format":false,"excerpt":"Die \"Abbreviated 510 (k)\u201c ist eines der drei 510(k)-Zulassungsverfahren, die die FDA anbietet. Dieser Artikel verr\u00e4t Ihnen, welche Arbeit Sie sich bei der Zulassung durch die \"Abbreviation\" sparen k\u00f6nnen, welche Voraussetzungen Sie daf\u00fcr erf\u00fcllen m\u00fcssen und weshalb der Begriff \"abbreviated\" irref\u00fchrend sein kann. 1. Abbreviated 510(k) und andere Zulassungsverfahren Wollen\u2026","rel":"","context":"In &quot;Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte&quot;","block_context":{"text":"Regulatory Affairs: Regulatorische Anforderungen an Medizinprodukte","link":"https:\/\/www.johner-institut.de\/blog\/category\/regulatory-affairs\/"},"img":{"alt_text":"FDA Approval Processes: 510(k), Abbreviated 510(k), PMA, ...","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/04\/FDA-Approval-Processes-510-k-PMA.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/04\/FDA-Approval-Processes-510-k-PMA.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/04\/FDA-Approval-Processes-510-k-PMA.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_shortlink":"https:\/\/wp.me\/pavawf-mw2B","jetpack_sharing_enabled":true,"authors":[{"term_id":1251,"user_id":110,"is_guest":0,"slug":"katharina-keutgen","display_name":"Katharina Keutgen","avatar_url":{"url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/05\/Katharina_Keutgen_300x300.png","url2x":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/05\/Katharina_Keutgen_300x300.png"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":"","9":""}],"_links":{"self":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/5366385","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/users\/110"}],"replies":[{"embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/comments?post=5366385"}],"version-history":[{"count":29,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/5366385\/revisions"}],"predecessor-version":[{"id":5381888,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/5366385\/revisions\/5381888"}],"wp:attachment":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/media?parent=5366385"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/categories?post=5366385"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/tags?post=5366385"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/ppma_author?post=5366385"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}