{"id":8782,"date":"2014-11-06T06:00:31","date_gmt":"2014-11-06T05:00:31","guid":{"rendered":"http:\/\/www.johner-institut.de\/blog\/?p=8782"},"modified":"2025-08-12T09:05:03","modified_gmt":"2025-08-12T07:05:03","slug":"customer-request-und-customer-requirement","status":"publish","type":"post","link":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/","title":{"rendered":"User Request und User Requirement"},"content":{"rendered":"\n<p>Wie identifiziert man die wirklichen User Requirements (Kundenanforderungen)? Einfach: Man fragt die User was Ihre Requirements (Anforderungen) seien. Falsch! So erfahren Sie nicht, was die User Requirements sind, sondern die User Requests! Diese Verwechslung kann das Scheitern Ihres Projekts bedeuten!<\/p>\n\n\n\n<!--more-->\n\n\n\n<h2 class=\"wp-block-heading\">1. Folgen der Verwechslung von User Requests und User Requirements<\/h2>\n\n\n\n<p>Auch ich glaubte verstanden zu haben, wie wichtig es ist, die Kundenanforderungen zu erfassen und umzusetzen. Daher fragte ich meine Kunden nach deren Anforderungen. Immer und immer wieder.<\/p>\n\n\n\n<p>Das Problem war nur, dass sich diese Anforderungen im Lauf der Zeit zu \u00e4ndern schienen. Dass immer wieder neue dazu kamen, daf\u00fcr andere unwichtiger wurden. Mein Team und ich iterierten dem hinterher. Das hat 100.000 EUR gekostet (eigentlich waren es mehr).<\/p>\n\n\n\n<p>Machen Sie nicht die gleichen Fehler wie ich, sparen Sie sich unn\u00f6tige Iterationen! Vermeiden Sie verz\u00f6gerte Entwicklungsprojekte, die aus dem Budget laufen!<\/p>\n\n\n\n<p><strong>Verwechseln Sie nicht User Requests und User Requirements!<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. User Requests<\/h2>\n\n\n\n<p>Ein <strong>User Request<\/strong> ist erst mal nichts weiter als ein Wunsch \u2014 von dem der Kunde nat\u00fcrlich behauptet, ihn zu brauchen. Meist werden User Requests im Sinn einer L\u00f6sungsskizze d.h. Blackbox-Bescheibung des Systems formuliert. Zum Beispiel \u201ek\u00f6nnen Sie die Tabelle nicht so machen, dass ich sie durch Klicken auf die Spaltenk\u00f6pfe sortieren kann\u201c (z.B. nach Behandlungsdatum) oder \u201ek\u00f6nnen Sie den Button XY hinzuf\u00fcgen\/verschieben\u201c. Damit sind die User Requests auf der Ebene der Systemanforderungen\/-Spezifikationen einzusortieren.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. User Requirements<\/h2>\n\n\n\n<p>Hinter diesen User Requests verbergen sich oft nicht explizit bewusste <strong>User Requirements<\/strong>, genauer gesagt \u201eUser Requirements\u201c auf deutsch <a href=\"https:\/\/www.johner-institut.de\/blog\/tag\/nutzungsanforderungen\/\">Nutzungsanforderungen<\/a>. Nutzungsanforderungen z\u00e4hlen zu den <a href=\"https:\/\/www.johner-institut.de\/blog\/tag\/stakeholder-anforderungen\/\">Stakeholder-Anforderungen<\/a> und sind definiert als \u201ean einem interaktiven System notwendige T\u00e4tigkeit in einer die T\u00e4tigkeit beschreibenden Weise, nicht in technisch realisierter.\u201c<\/p>\n\n\n\n<p>Eine Nutzungsanforderungen k\u00f6nnte lauten (passend zu obigem User Request): \u201eDer Nutzer muss am System die Patienten, die zuletzt behandelt wurden erkennen k\u00f6nnen\u201c. Als Verb stehen nur \u201eeingeben&#8220;, \u201eausw\u00e4hlen\u201c oder kognitive Leistungen wie hier \u201eerkennen\u201c zur Auswahl.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Vom User Request zum User Requirement<\/h2>\n\n\n\n<p>User Requirements sollte man systematisch herleiten. Dazu gibt es Verfahren. Das direkte Befragen der Nutzer nach W\u00fcnschen ist nicht zielf\u00fchrend wie <a href=\"https:\/\/de.wikipedia.org\/wiki\/Henry_Ford\">Henry Ford<\/a> schon wusste:<\/p>\n\n\n\n<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\">\n<p>\u201eWenn ich meine Kunden gefragt h\u00e4tte, was sie brauchen, h\u00e4tten sie gesagt &#8222;schnellere Pferde&#8220;.<\/p>\n<\/blockquote>\n\n\n\n<p>Oder um es mit Steve Jobs zu sagen: Es ist nicht die Aufgabe der Kunden zu wissen, was sie wollen. Das h\u00f6rt sich arrogant an, stimmt aber. Es ist Aufgabe des Produktmanagements aus einem Kontext die Nutzungsanforderungen (user requirements) abzuleiten. Die Kundenw\u00fcnsche sollten meist nur der Anlass sein, die wirklichen Anforderungen zu erheben.<\/p>\n\n\n\n<p>Wer das nicht versteht, wird auch nicht verstehen, weshalb 45% der implementierten Funktionalit\u00e4ten \u00fcberhaupt nicht ben\u00f6tigt werden. Hier wurden requests mit requirements verwechselt. Eine teure Angelegenheit.<\/p>\n\n\n\n<p>Wer wissen will, wie man wirklich zu Nutzungs- und Systemanforderungen kommt, sollte nach Konstanz zum <a title=\"Seminar Usability, Requirements, IEC 62366\" href=\"https:\/\/www.johner-institut.de\/seminare\/usability-requirements-en62366.html\">Seminar Usability, Requirements und IEC 62366<\/a> kommen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. Gefahren beim Verwechseln von User Request und User Requirement<\/h2>\n\n\n\n<p>Viele gehen sorglos mit dem Begriffspaar <strong>Request<\/strong> und <strong>Requirement<\/strong> um. Regelm\u00e4\u00dfig h\u00f6re ich in Firmen, dass ein &#8222;User requirement&#8220; zu erf\u00fcllen sei. Wenn ich mir dann ansehe, was das ist, handelt es sich aber gar nicht um ein User requirement, sondern schlicht um eine Kundenanfrage oder einen Kundenwunsch. Und eben nicht um ein Requirement. Das kann unangenehme Folgen haben:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Projektverzug und Kosten\u00fcberschreitung<\/strong>: Wenn Sie nicht die wahren User Requirements identifizieren, sondern die User Requests direkt implementieren, werden Ihre Kunden st\u00e4ndig neue &#8222;Anforderungen&#8220; an Sie herantragen. Sie werden st\u00e4ndig nachbessern, was die Kosten enorm in die H\u00f6he treibt. Es kann sogar soweit kommen, dass Sie das Projekt abbrechen, weil neue W\u00fcnsche mit der urspr\u00fcnglichen Architektur bzw. Technologie \u00fcberhaupt nicht mehr zu realisieren sind.<\/li>\n\n\n\n<li><strong>Probleme bei der Zulassung und im Audit<\/strong>: Die ISO 13485 und FDA unterscheiden sehr wohl zwischen Systemspezifikationen und Stakeholder-Anforderungen. Zwischen beiden m\u00fcssen Sie &#8222;tracen&#8220;. Wenn Sie aber glauben, dass die User Request User Requirements seien, wird dieses Tracing zu einem Verweis im Kreis, damit absurd und so zu einem potenziellen Problem.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Wie identifiziert man die wirklichen User Requirements (Kundenanforderungen)? Einfach: Man fragt die User was Ihre Requirements (Anforderungen) seien. Falsch! So erfahren Sie nicht, was die User Requirements sind, sondern die User Requests! Diese Verwechslung kann das Scheitern Ihres Projekts bedeuten!<\/p>\n","protected":false},"author":71,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":true,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[1102],"tags":[294,332,802,1096],"ppma_author":[1265],"class_list":["post-8782","post","type-post","status-publish","format-standard","hentry","category-iec-62366-usability","tag-nutzungsanforderungen","tag-requirements","tag-stakeholder-anforderungen","tag-validierung","category-1102","description-off"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>User Request und User Requirement<\/title>\n<meta name=\"description\" content=\"Wenn Sie Uer Request und User Requirement verwechseln, drohen Ihnen unn\u00f6tige Iterationen und verz\u00f6gerte Projekte.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"User Request und User Requirement\" \/>\n<meta property=\"og:description\" content=\"Wenn Sie Uer Request und User Requirement verwechseln, drohen Ihnen unn\u00f6tige Iterationen und verz\u00f6gerte Projekte.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/\" \/>\n<meta property=\"og:site_name\" content=\"Regulatorisches Wissen f\u00fcr Medizinprodukte\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/JohnerInstitut\/\" \/>\n<meta property=\"article:published_time\" content=\"2014-11-06T05:00:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-12T07:05:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2020\/06\/ji.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"501\" \/>\n\t<meta property=\"og:image:height\" content=\"266\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Dr. Philipp Schleer\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dr. Philipp Schleer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/\"},\"author\":{\"name\":\"Dr. Philipp Schleer\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/person\\\/167041ac9fced451b3f018b7842cf015\"},\"headline\":\"User Request und User Requirement\",\"datePublished\":\"2014-11-06T05:00:31+00:00\",\"dateModified\":\"2025-08-12T07:05:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/\"},\"wordCount\":671,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\"},\"keywords\":[\"Nutzungsanforderungen erheben und nachweisen\",\"Requirements \\\/ Anforderungen\",\"Stakeholder-Anforderungen erheben und pr\u00fcfen\",\"Validierung: Regulatorische Anforderungen erf\u00fcllen\"],\"articleSection\":[\"Usability &amp; IEC 62366-1\"],\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/\",\"name\":\"User Request und User Requirement\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#website\"},\"datePublished\":\"2014-11-06T05:00:31+00:00\",\"dateModified\":\"2025-08-12T07:05:03+00:00\",\"description\":\"Wenn Sie Uer Request und User Requirement verwechseln, drohen Ihnen unn\u00f6tige Iterationen und verz\u00f6gerte Projekte.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/iec-62366-usability\\\/customer-request-und-customer-requirement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Usability &amp; IEC 62366-1\",\"item\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/category\\\/iec-62366-usability\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"User Request und User Requirement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\",\"name\":\"Regulatorisches Wissen f\u00fcr Medizinprodukte\",\"description\":\"Fachartikel zur Entwicklung und Zulassung von Medizinprodukten und weiteren regulatorischen Themen\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#organization\",\"name\":\"Johner Institut GmbH\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/07\\\/Johner-Institut.png\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2015\\\/07\\\/Johner-Institut.png\",\"width\":1213,\"height\":286,\"caption\":\"Johner Institut GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/JohnerInstitut\\\/\",\"https:\\\/\\\/x.com\\\/christianjohner\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/JohnerInstitut\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/#\\\/schema\\\/person\\\/167041ac9fced451b3f018b7842cf015\",\"name\":\"Dr. Philipp Schleer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Portrait_1-750x750-Philipp_Schleer.jpgd83e70e1ca634d6dfa6e6775e8c19413\",\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Portrait_1-750x750-Philipp_Schleer.jpg\",\"contentUrl\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Portrait_1-750x750-Philipp_Schleer.jpg\",\"caption\":\"Dr. Philipp Schleer\"},\"url\":\"https:\\\/\\\/www.johner-institut.de\\\/blog\\\/author\\\/philipp-schleer\\\/\"}]}<\/script>\n<meta name=\"copyright\" content=\"Johner Institut GmbH\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"User Request und User Requirement","description":"Wenn Sie Uer Request und User Requirement verwechseln, drohen Ihnen unn\u00f6tige Iterationen und verz\u00f6gerte Projekte.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/","og_locale":"de_DE","og_type":"article","og_title":"User Request und User Requirement","og_description":"Wenn Sie Uer Request und User Requirement verwechseln, drohen Ihnen unn\u00f6tige Iterationen und verz\u00f6gerte Projekte.","og_url":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/","og_site_name":"Regulatorisches Wissen f\u00fcr Medizinprodukte","article_publisher":"https:\/\/www.facebook.com\/JohnerInstitut\/","article_published_time":"2014-11-06T05:00:31+00:00","article_modified_time":"2025-08-12T07:05:03+00:00","og_image":[{"width":501,"height":266,"url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2020\/06\/ji.jpg","type":"image\/jpeg"}],"author":"Dr. Philipp Schleer","twitter_misc":{"Verfasst von":"Dr. Philipp Schleer","Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/#article","isPartOf":{"@id":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/"},"author":{"name":"Dr. Philipp Schleer","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/person\/167041ac9fced451b3f018b7842cf015"},"headline":"User Request und User Requirement","datePublished":"2014-11-06T05:00:31+00:00","dateModified":"2025-08-12T07:05:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/"},"wordCount":671,"commentCount":0,"publisher":{"@id":"https:\/\/www.johner-institut.de\/blog\/#organization"},"keywords":["Nutzungsanforderungen erheben und nachweisen","Requirements \/ Anforderungen","Stakeholder-Anforderungen erheben und pr\u00fcfen","Validierung: Regulatorische Anforderungen erf\u00fcllen"],"articleSection":["Usability &amp; IEC 62366-1"],"inLanguage":"de","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/","url":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/","name":"User Request und User Requirement","isPartOf":{"@id":"https:\/\/www.johner-institut.de\/blog\/#website"},"datePublished":"2014-11-06T05:00:31+00:00","dateModified":"2025-08-12T07:05:03+00:00","description":"Wenn Sie Uer Request und User Requirement verwechseln, drohen Ihnen unn\u00f6tige Iterationen und verz\u00f6gerte Projekte.","breadcrumb":{"@id":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/customer-request-und-customer-requirement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Blog","item":"https:\/\/www.johner-institut.de\/blog\/"},{"@type":"ListItem","position":2,"name":"Usability &amp; IEC 62366-1","item":"https:\/\/www.johner-institut.de\/blog\/category\/iec-62366-usability\/"},{"@type":"ListItem","position":3,"name":"User Request und User Requirement"}]},{"@type":"WebSite","@id":"https:\/\/www.johner-institut.de\/blog\/#website","url":"https:\/\/www.johner-institut.de\/blog\/","name":"Regulatorisches Wissen f\u00fcr Medizinprodukte","description":"Fachartikel zur Entwicklung und Zulassung von Medizinprodukten und weiteren regulatorischen Themen","publisher":{"@id":"https:\/\/www.johner-institut.de\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.johner-institut.de\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.johner-institut.de\/blog\/#organization","name":"Johner Institut GmbH","url":"https:\/\/www.johner-institut.de\/blog\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/07\/Johner-Institut.png","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/07\/Johner-Institut.png","width":1213,"height":286,"caption":"Johner Institut GmbH"},"image":{"@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/JohnerInstitut\/","https:\/\/x.com\/christianjohner","https:\/\/www.youtube.com\/user\/JohnerInstitut"]},{"@type":"Person","@id":"https:\/\/www.johner-institut.de\/blog\/#\/schema\/person\/167041ac9fced451b3f018b7842cf015","name":"Dr. Philipp Schleer","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/10\/Portrait_1-750x750-Philipp_Schleer.jpgd83e70e1ca634d6dfa6e6775e8c19413","url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/10\/Portrait_1-750x750-Philipp_Schleer.jpg","contentUrl":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/10\/Portrait_1-750x750-Philipp_Schleer.jpg","caption":"Dr. Philipp Schleer"},"url":"https:\/\/www.johner-institut.de\/blog\/author\/philipp-schleer\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack-related-posts":[{"id":3865,"url":"https:\/\/www.johner-institut.de\/blog\/systems-engineering\/produktmanager\/","url_meta":{"origin":8782,"position":0},"title":"Was macht eigentlich ein Produktmanager? M\u00fcssen die uns leidtun?","author":"Prof. Dr. Christian Johner","date":"9. M\u00e4rz 2016","format":false,"excerpt":"Beim Wort \"Produktmanager\" oder \"Produktmanagement\" verdrehen viele Entwickler die Augen. Die Zusammenarbeit der beiden Abteilungen ist oft von Reibungsverlusten gepr\u00e4gt. Lesen Sie hier, weshalb dem so ist und was Sie dagegen machen k\u00f6nnen. Produktmanager: Status quo Eigenwahrnehmung der Produktmanager Viele Produktmanager haben das Gef\u00fchl, f\u00fcr all das zust\u00e4ndig zu sein,\u2026","rel":"","context":"In &quot;Systems Engineering bei Medizinprodukten&quot;","block_context":{"text":"Systems Engineering bei Medizinprodukten","link":"https:\/\/www.johner-institut.de\/blog\/category\/systems-engineering\/"},"img":{"alt_text":"Produktmanager","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2012\/02\/020812_2138_Wasmachteig1.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":7418,"url":"https:\/\/www.johner-institut.de\/blog\/iec-62304-medizinische-software\/gesetzliche-anforderungen-an-medizinprodukte-formulierungsschablone\/","url_meta":{"origin":8782,"position":1},"title":"Gesetzliche Anforderungen an Medizinprodukte: Formulierungsschablone","author":"Prof. Dr. Christian Johner","date":"3. Februar 2015","format":false,"excerpt":"Dieser Artikel beschreibt, was gesetzliche Anforderungen sind, wie\u00a0diese mit Stakeholder-Anforderungen und System-Anforderungen zusammenspielen, welche gesetzlichen Anforderungen es an deren Dokumentation gibt und wie Sie gesetzliche Anforderungen formulieren und damit dokumentieren k\u00f6nnen. Gesetzliche Anforderungen versus Stakeholder-Anforderungen versus System-Anforderungen Gesetzliche Anforderungen z\u00e4hlen zu den Stakeholder-Anforderungen Unter gesetzlichen Anforderungen\u00a0subsumieren wir hier alle Anforderungen,\u2026","rel":"","context":"In &quot;Software &amp; IEC 62304&quot;","block_context":{"text":"Software &amp; IEC 62304","link":"https:\/\/www.johner-institut.de\/blog\/category\/iec-62304-medizinische-software\/"},"img":{"alt_text":"Gesetzliche Anforderungen m\u00fcssen f\u00fcr Medizinprodukte dokumentiert werden","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2014\/04\/Gesetzliche-Anforderungen-300x115.png?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":11732,"url":"https:\/\/www.johner-institut.de\/blog\/qualitaetsmanagement-iso-13485\/design-input\/","url_meta":{"origin":8782,"position":2},"title":"Design Input: Was Sie nicht vergessen sollten","author":"Dr. Sophie Bartsch","date":"20. Februar 2017","format":false,"excerpt":"Unter\u00a0\"Design\u00a0Input\"\u00a0versteht man die Entwicklungsvorgaben, an die nicht nur die FDA konkrete Forderungen stellt. Dieser Artikel beschreibt, welche Inhalte Ihr Design Input enthalten sollte. Sie erfahren,\u00a0wie das Risikomanagement mit dem Design Input zusammenspielt. \u00a0Inhalts\u00fcbersicht Definition \"Design Input\" \u00bb Regulatorische Anorderungen \u00bb Inhalte des Design Inputs \u00bb Risikoanalyse als Design Input \u00bb\u2026","rel":"","context":"In &quot;Qualit\u00e4tsmanagement &amp; ISO 13485&quot;","block_context":{"text":"Qualit\u00e4tsmanagement &amp; ISO 13485","link":"https:\/\/www.johner-institut.de\/blog\/category\/qualitaetsmanagement-iso-13485\/"},"img":{"alt_text":"Der Design Input ist das Ergebnis einer Analyse, Bewertung und Umsetzung der Zweckbestimmung und Stakeholder-Anforderungen","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/09\/Design-Input.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/09\/Design-Input.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2015\/09\/Design-Input.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":1203570,"url":"https:\/\/www.johner-institut.de\/blog\/iec-62366-usability\/personas\/","url_meta":{"origin":8782,"position":3},"title":"&#8218;Personas&#8216;: die 5 h\u00e4ufigsten Fehler vermeiden","author":"Prof. Dr. Christian Johner","date":"8. Mai 2018","format":false,"excerpt":"Viele Firmen verwenden\u00a0Personas als Methode im Usability und Requirements Engineering. Eine Persona ist eine fiktive Person, die als repr\u00e4sentativer Vertreter einer Gruppe dient, typischerweise einer Gruppe potenzieller Benutzer eines Systems. Besonders in der agilen Software-Entwicklung sowie bei Marketing- und Design-Agenturen sind Personas beliebt. Doch die Methode wird h\u00e4ufig missverstanden und\u2026","rel":"","context":"In &quot;Usability &amp; IEC 62366-1&quot;","block_context":{"text":"Usability &amp; IEC 62366-1","link":"https:\/\/www.johner-institut.de\/blog\/category\/iec-62366-usability\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/05\/Personas-Beispiel-klein.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/05\/Personas-Beispiel-klein.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2018\/05\/Personas-Beispiel-klein.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":4211,"url":"https:\/\/www.johner-institut.de\/blog\/iec-62304-medizinische-software\/v-modell\/","url_meta":{"origin":8782,"position":4},"title":"V-Modell: Die 5 h\u00e4ufigsten Probleme vermeiden","author":"Mario Klessascheck","date":"23. Mai 2023","format":false,"excerpt":"Das V-Modell ist ein Entwicklungsprozessmodell, das urspr\u00fcnglich bei staatlichen Projekten (u. a. R\u00fcstung) zur Anwendung kam. Bis heute ist es bei Projekten im regulierten Umfeld (z. B. Medizintechnik, Banken) in vielen K\u00f6pfen und Normen verankert. Das f\u00fchrt zu Konflikten in Teams, die agile Entwicklungsprozesse bevorzugen. Dieser Artikel hilft, diesen Widerspruch\u2026","rel":"","context":"In &quot;Software &amp; IEC 62304&quot;","block_context":{"text":"Software &amp; IEC 62304","link":"https:\/\/www.johner-institut.de\/blog\/category\/iec-62304-medizinische-software\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/V-Modell-Phasen.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/V-Modell-Phasen.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2023\/05\/V-Modell-Phasen.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":2046,"url":"https:\/\/www.johner-institut.de\/blog\/iec-62304-medizinische-software\/agile-softwareentwicklung-fuer-medizinprodukte\/","url_meta":{"origin":8782,"position":5},"title":"Agile Softwareentwicklung f\u00fcr Medizinprodukte","author":"Daniel Reinsch","date":"28. Januar 2019","format":false,"excerpt":"Viele Medizinproduktehersteller schw\u00f6ren auf die agile Softwareentwicklung. Der nicht nur rechtlichen Implikationen ist man sich aber h\u00e4ufig nicht bewusst. 1. Agile Softwareentwicklung allgemein a) Historie, Motivation Die agile Softwareentwicklung entstand quasi als Gegenbewegung zu dem Trend, immer mehr Dokumente bei der Software-Entwicklung zu verlangen,die Entwickler zunehmend auf deren Rollen zu\u2026","rel":"","context":"In &quot;Software &amp; IEC 62304&quot;","block_context":{"text":"Software &amp; IEC 62304","link":"https:\/\/www.johner-institut.de\/blog\/category\/iec-62304-medizinische-software\/"},"img":{"alt_text":"Auch Mini-Vs f\u00fcr die agile Softwareentwicklung f\u00fcr Medizinprodukte f\u00fchren nicht immer zur IEC 62304 Konformit\u00e4t","src":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2011\/10\/102011_2137_DieMiniVsd1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2011\/10\/102011_2137_DieMiniVsd1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/www.johner-institut.de\/blog\/wp-content\/uploads\/2011\/10\/102011_2137_DieMiniVsd1.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_shortlink":"https:\/\/wp.me\/pavawf-2hE","jetpack_sharing_enabled":true,"authors":[{"term_id":1265,"user_id":71,"is_guest":0,"slug":"philipp-schleer","display_name":"Dr. Philipp Schleer","avatar_url":{"url":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/10\/Portrait_1-750x750-Philipp_Schleer.jpg","url2x":"https:\/\/www.johner-institut.de\/blog\/wp-content\/uploads\/2024\/10\/Portrait_1-750x750-Philipp_Schleer.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":"","9":""}],"_links":{"self":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/8782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/users\/71"}],"replies":[{"embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/comments?post=8782"}],"version-history":[{"count":15,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/8782\/revisions"}],"predecessor-version":[{"id":5381628,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/posts\/8782\/revisions\/5381628"}],"wp:attachment":[{"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/media?parent=8782"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/categories?post=8782"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/tags?post=8782"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.johner-institut.de\/blog\/wp-json\/wp\/v2\/ppma_author?post=8782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}